-
Rebar RetrofitThis shows the first stage of the process, retrofitting the rebar structure to the existing concrete roof. -
Concrete BermThe completed concrete berm provides protection for the panels and a surface on which to mount the according shutters. -
Ground ConnectionAll rails are grounded using nickel-plated brass connectors soldered onto solid copper wire and bolted in place -
Junction Box connectionAll connections are made in weatherproof aluminium junction boxes. All grouding connections in junction boxes are made using nickel-plated brass lugs soldered onto solid copper wire and screwed in place -
ConduitAll wires are run within conduit which is encased in concrete whereever it is directly expoesed to the elements -
Rail MaterialsAll materials for the rail mounts are stainless and aluminium. Anti-galvanizing compound is used wherever dissimilar metals meet. -
-
Panels Mounted within the bermsAnother view of the panels mounted within the berms -
-
-
-
-
-
